Difference between revisions of "RS232 to RS422/RS485 Serial Converter-CQR1218"
(→SPECIFICATION) |
(→Communication Link Diagram) |
||
(35 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | [[File: | + | [[File:CQR1218-1.jpg| right |thumb|400px|RS232 to RS422/RS485 Serial Converter]] |
− | ==''' | + | =='''Introduction'''== |
CQR1218 is a universal RS232 to RS485/RS422 bidirectional converter, designed to extend the RS232 transmission distance and the interface converter designed for the RS485/RS422 bus, which consists of a number of CQRobot independent innovation technology. It Includes built-in data collision protection control, the power supply and signal lights and inhibition of TVS transient voltages protection. In order to adapt to RS422 / RS485 with much bus wiring, it provides a terminal at port, DB9 and RJ45 physical interface, that effectively adapt to a variety of connection mode, making the bus from multiple directions to be better contacted and more convenient to be implemented. The equipment adopts the aluminum shell of sandblasting and anti-oxidation, which can effectively shield the external interference and have good heat dissipation. | CQR1218 is a universal RS232 to RS485/RS422 bidirectional converter, designed to extend the RS232 transmission distance and the interface converter designed for the RS485/RS422 bus, which consists of a number of CQRobot independent innovation technology. It Includes built-in data collision protection control, the power supply and signal lights and inhibition of TVS transient voltages protection. In order to adapt to RS422 / RS485 with much bus wiring, it provides a terminal at port, DB9 and RJ45 physical interface, that effectively adapt to a variety of connection mode, making the bus from multiple directions to be better contacted and more convenient to be implemented. The equipment adopts the aluminum shell of sandblasting and anti-oxidation, which can effectively shield the external interference and have good heat dissipation. | ||
Line 12: | Line 12: | ||
To prevent the reflection and interference of the signal, a matching resistor is needed at the terminal of the line (the parameter is 120 ohm 1/4w) when the converter is used as full duplex or half duplex wiring. | To prevent the reflection and interference of the signal, a matching resistor is needed at the terminal of the line (the parameter is 120 ohm 1/4w) when the converter is used as full duplex or half duplex wiring. | ||
− | ==''' | + | =='''Features'''== |
*Built-in data collision protection control DCPC function. | *Built-in data collision protection control DCPC function. | ||
*The baud rate is adaptive | *The baud rate is adaptive | ||
Line 24: | Line 24: | ||
*Plug-and-Play, NO Need to Drive. Supports Windows98 / Windows2000 / XP / Vista / Win7 / Win8 / Win10 / ME, Linux, MAC, Android, Arduino. | *Plug-and-Play, NO Need to Drive. Supports Windows98 / Windows2000 / XP / Vista / Win7 / Win8 / Win10 / ME, Linux, MAC, Android, Arduino. | ||
− | == | + | =='''Apllacations'''== |
* Singlechip, Surveillance Camera | * Singlechip, Surveillance Camera | ||
Line 37: | Line 37: | ||
Factory automation system, Distributed control system, Other 485/422 serial device wireless network, LED INFO display equipments, PLC control and management, SCADA, measuring instruments and monitoring system, CNC management, Medical treatment/medication automation, Building automation, Check on work attendance/Human resource management | Factory automation system, Distributed control system, Other 485/422 serial device wireless network, LED INFO display equipments, PLC control and management, SCADA, measuring instruments and monitoring system, CNC management, Medical treatment/medication automation, Building automation, Check on work attendance/Human resource management | ||
− | ==Display== | + | =='''Display'''== |
{|- | {|- | ||
− | |[[File: | + | |[[File:CQR1218-2.jpg |left|300px]] |
− | |[[File: | + | |[[File:CQR1218-3.jpg |none|300px]] |
− | |[[File: | + | |[[File:CQR1218-4.jpg |none|300px]] |
+ | |[[File:CQR1218-5.jpg |none|300px]] | ||
|} | |} | ||
---- | ---- | ||
{|- | {|- | ||
− | |[[File: | + | |[[File:CQR1218-6.jpg |left|300px]] |
− | |[[File: | + | |[[File:CQR1218-7.jpg |none|300px]] |
− | |[[File: | + | |[[File:CQR1218-8.jpg |none|300px]] |
+ | |[[File:CQR1218-9.jpg |none|300px]] | ||
+ | |||
|} | |} | ||
---- | ---- | ||
− | == | + | =='''Specification'''== |
*Working Voltage: 9V-18V / DC, Power Supply For RS232 to RS422/RS485 Serial Converter With EU UK US Plug. | *Working Voltage: 9V-18V / DC, Power Supply For RS232 to RS422/RS485 Serial Converter With EU UK US Plug. | ||
*Interface characteristics: The interface is compatible with EIA/TIA's RS-232c, RS-485 / rs-422 standard. | *Interface characteristics: The interface is compatible with EIA/TIA's RS-232c, RS-485 / rs-422 standard. | ||
Line 66: | Line 69: | ||
---- | ---- | ||
− | == | + | =='''Connectors and Signals'''== |
+ | {|- | ||
+ | |[[File:CQR1218-10.jpg |left|400px]] | ||
+ | |[[File:CQR1218-11.jpg |none|430px]] | ||
+ | |} | ||
+ | ---- | ||
+ | |||
+ | =='''Hardware Installation and Application'''== | ||
+ | Please read the instructions carefully before installing the dt-9018 interface converter. Connect the communication cable of the product to the RS-232 interface, and make sure the power adapter is connected to the socket. This product uses the general connector as the input/output interface, and no jumper setting and it can automatically realize the RS-485 or RS-422 communication mode. Double stranded wire or shielded wire can be used. It is very convenient to connect and disassemble. T/R+T/R- for launch, RXD+/RXD- for reception, VCC for input or output power, GND for public ground, Point-to-point, point-to-points, half-duplex communication to two lines T/R+, T/R-, point to point, point to point, full-duplex communication to four lines T/R+, T/R-, RXD+, RXD-. | ||
+ | =='''Communication Link Diagram'''== | ||
+ | '''RS-232 to RS-422 conversion''' | ||
+ | {|- | ||
+ | |[[File:CQR1218-12.jpg |left|380px]] | ||
+ | |[[File:CQR1218-13.jpg |none|400px]] | ||
+ | |[[File:CQR1218-14.jpg |none|380px]] | ||
+ | |} | ||
+ | ---- | ||
+ | |||
+ | '''RS-232 to RS-485 conversion''' | ||
+ | {|- | ||
+ | |[[File:CQR1218-15.jpg |left|380px]] | ||
+ | |[[File:CQR1218-16.jpg |none|400px]] | ||
+ | |[[File:CQR1218-17.jpg |none|380px]] | ||
+ | |} | ||
+ | ---- | ||
+ | |||
+ | =='''Distrbution List'''== | ||
− | |||
*1 * Serial Cable | *1 * Serial Cable | ||
*1 * DB9 to 5P Converter | *1 * DB9 to 5P Converter | ||
+ | *1 * DC 9V-18V Power Supply, With EU UK US Plug. | ||
+ | *1 * RS232 to RS485/RS422 Convertor with Charger. |
Latest revision as of 18:36, 15 May 2018
Contents
Introduction
CQR1218 is a universal RS232 to RS485/RS422 bidirectional converter, designed to extend the RS232 transmission distance and the interface converter designed for the RS485/RS422 bus, which consists of a number of CQRobot independent innovation technology. It Includes built-in data collision protection control, the power supply and signal lights and inhibition of TVS transient voltages protection. In order to adapt to RS422 / RS485 with much bus wiring, it provides a terminal at port, DB9 and RJ45 physical interface, that effectively adapt to a variety of connection mode, making the bus from multiple directions to be better contacted and more convenient to be implemented. The equipment adopts the aluminum shell of sandblasting and anti-oxidation, which can effectively shield the external interference and have good heat dissipation.
CQR1218 interface converter supports the following four communication modes:
- Point to point / 4 full duplex.
- Point to multi-points/four-line full-duplex.
- Point to point/twine and half duplex.
- Point to multi-points/two-line and half duplex.
To prevent the reflection and interference of the signal, a matching resistor is needed at the terminal of the line (the parameter is 120 ohm 1/4w) when the converter is used as full duplex or half duplex wiring.
Features
- Built-in data collision protection control DCPC function.
- The baud rate is adaptive
- LED indicates power and signal status.
- The maximum support is 32 nodes.
- RS232 port protection: 15KV ESD.
- The RS485/RS422 port provides surge protection. With Lightning protection of 600W.
- The data is bidirectional.
- 9V-18V / DC, Power Supply, With EU UK US Plug.
- It does not require a handshake signal to achieve transparent transmission.
- Plug-and-Play, NO Need to Drive. Supports Windows98 / Windows2000 / XP / Vista / Win7 / Win8 / Win10 / ME, Linux, MAC, Android, Arduino.
Apllacations
- Singlechip, Surveillance Camera
- Barcode Scanner
- Fingerprint Attendance Machine
- Computer PDA (WINCE system)
- Label Printer
- Engineering Exchange
- Industrial Control
- Safety Access Control
Factory automation system, Distributed control system, Other 485/422 serial device wireless network, LED INFO display equipments, PLC control and management, SCADA, measuring instruments and monitoring system, CNC management, Medical treatment/medication automation, Building automation, Check on work attendance/Human resource management
Display
Specification
- Working Voltage: 9V-18V / DC, Power Supply For RS232 to RS422/RS485 Serial Converter With EU UK US Plug.
- Interface characteristics: The interface is compatible with EIA/TIA's RS-232c, RS-485 / rs-422 standard.
- Electrical interface: Connector with RS-232 interface to input DB9; RS-422 / RS-485 interface: Terminal, RJ-45 and DB9.
- Protection level: RS-422, RS-485 interface with 600W lightning surge protection of each line.
- Working mode: Half-duplex asynchronous or full-duplex asynchronous.
- Signal indication: Three signal indicator light of power supply (PWR), send (TXD), receive (RXD).
- Transmission medium: Twisted pair or shielded wire.
- Transmission rate: 115.2k BPS to 300M/38.4 K BPS to 38.4 KM/9600 BPS to 5 km.
- Dimensions: 113mm * 55mm * 25mm.
- The using of environment: 25 Degree Celsius to 70 Degree Celsius, relative humidity of 5% to 95%.
- Transmission distance: 1200 m (115200bps-9600bps).
Connectors and Signals
Hardware Installation and Application
Please read the instructions carefully before installing the dt-9018 interface converter. Connect the communication cable of the product to the RS-232 interface, and make sure the power adapter is connected to the socket. This product uses the general connector as the input/output interface, and no jumper setting and it can automatically realize the RS-485 or RS-422 communication mode. Double stranded wire or shielded wire can be used. It is very convenient to connect and disassemble. T/R+T/R- for launch, RXD+/RXD- for reception, VCC for input or output power, GND for public ground, Point-to-point, point-to-points, half-duplex communication to two lines T/R+, T/R-, point to point, point to point, full-duplex communication to four lines T/R+, T/R-, RXD+, RXD-.
Communication Link Diagram
RS-232 to RS-422 conversion
RS-232 to RS-485 conversion
Distrbution List
- 1 * Serial Cable
- 1 * DB9 to 5P Converter
- 1 * DC 9V-18V Power Supply, With EU UK US Plug.
- 1 * RS232 to RS485/RS422 Convertor with Charger.